0

Your Cart is Empty

Add an Additional Layer of Safety for In-Drawer Outlets

Install a Safety Interlock Outlet with Blade Limit Switch along with any 15 amp Blade Series in-drawer outlet for an extra layer of safety in powered drawers.

*Only for use with Blade Series in-drawer outlets. For general applications, such as cabinet doors, choose the General Purpose Limit Switch.

Add an Additional Layer of Safety for In-Drawer Outlets

Install a Safety Interlock Outlet with Blade Limit Switch along with any 15 amp Blade Series in-drawer outlet for an extra layer of safety in powered drawers.

*Only for use with Blade Series in-drawer outlets. For general applications, such as cabinet doors, choose the General Purpose Limit Switch.

Added Layer of Safety

Blade Series Limit Switch mounts to any 15 amp Docking Drawer Blade Series outlet to detect drawer position and de-energizes the outlet when the drawer starts to close.

Simple to Install

The 15 amp Safety Interlock Outlet simply installs into a standard single gang junction box within 4' of the 15 amp Blade Series outlet.

ETL Listed for US and Canada

All Docking Drawer Blade Series Outlets are listed to UL 962a and CSA 22.2 #21, and the Safety Interlock Outlet with Blade Limit Switch is listed to UL 498 and CSA 22.2 #42.

How It Works

*Only for use with Blade Series outlets

Docking Drawer’s 15 amp Safety Interlock Outlet is a single gang electrical outlet featuring one NEMA 5-15 receptacle and one interlock switch connector. Blade Series Limit Switch mounts to any 15 amp Docking Drawer Blade Series outlet to detect the drawer position and de-energize the connected Docking Drawer outlet (as well as the Safety Interlock Outlet itself) when the drawer is closed.

The Blade Limit Switch should de-energize the Blade Series outlet when the drawer is 1-2” from the fully open position. You may find it is necessary to further adjust the position of the Blade Limit Switch to de-energize the outlet at the correct drawer position to achieve proper operation.

ETL Listed for the US and Canada

All Docking Drawer Blade Series Outlets are listed to UL 962a and CSA 22.2 #21, and the Safety Interlock Outlet with Blade Limit Switch is listed to UL 498 and CSA 22.2 #42. *The Authorities Having Jurisdiction (AHJ) has the final say on whether an installation meets the requirements of the Canadian Electrical Code.

Applications

Bathroom Vanities

appliance smoke detector

Appliance Drawers

dishwasher fire safety

Project Gallery

Shop 15 amp Safety Interlock Outlet with Blade Limit Switch

cabinet drawer electrical outlet

15 amp Safety Interlock Outlet with Blade Limit Switch

$79

Quick Specs
  • Mounts to any 15 amp Docking Drawer Blade Series outlet
  • Detects the drawer position and will de-energize the outlet when the drawer starts to close
  • Limit Switch is adjustable so the drawer can de-energize in the correct position
  • Get Specifications

“That’s the beauty of your [product]! It activates at the earliest possible moment and kills the power creating the opportunity for either self-extinguishment, or better yet, no fire at all. I teach a monthly fire extinguisher class where I tell the students that “if you can de-energize the equipment, 90% or the majority of time the fire will self-extinguish.”

– RICH D.  RETIRED FIRE CHIEF